Cumulus.ini (preserving history): Difference between revisions

m
m (→‎Section: Station: Chill hours)
*0 = Disabled
*1 = Enabled, Cumulus will calculate the dew point instead of using the value supplied by the station. This avoids the restriction in the Oregon Scientific stations where the dew point can never be below freezing point.
 
|-
|CalculatedWC=0
*0 = Disabled
*1 = Enabled, Cumulus will calculate the wind chill instead of using the value supplied by the station. Note that some stations (Fine Offset, for example, do not supply a wind chill value anyway, so Cumulus always calculates it). You should set this if you have specified any calibration values for wind or temperature, so that Cumulus can also apply those values to the wind chill.
|-
|UseWindChillCutOff=1
|Calculate [[Wind chill]] only if temperature less than 10°C rule.
*0 = Disabled (default)
*1 = Enabled, this line needs to be added in the [Station] section of the Cumulus.ini
Note that you need to set Cumulus to calculate the wind chill (if your station is a type that supplies one itself) for this setting to have any effect.
|-
|ChillHourSeasonStart=10
|The season start figure is the calendar month number (1 to 12)
|-
|ChillHourThreshold=45
|The temperature threshold is specified in the units that you use in Cumulus (see [[Heat/cold_degree_days_and_Chill_hours]]
|-
|RolloverHour=0
*0 = Use 10am in summer not checked on Station Configuration Screen
*1 = Use 10am in summer selected on Station Configuration Screen
|-
|
SnowDepthHour=9
|Snow lying/falling roll over time (time when yesterday's values in log.xml are forgotten)
*0 = midnight
*9 = 9am
|-
|ConfirmClose=0
|EWpressureoffset=x.y
|Got a pressure problem with a Fine Offset station? This can occur on startup when the pressure 'offset' that Cumulus reads is garbage, so Cumulus just uses zero (so effectively you end up with your absolute pressure being recorded instead of relative pressure). There's a work around for this by telling Cumulus what offset to use, rather than reading it from the station. You specify it in cumulus.ini by adding a line to the [Station] section: where x.y is the difference between your station (absolute) and sea-level (relative) pressures, in mb/hPA.
|-
|UseWindChillCutOff=1
|Calculate [[Wind chill]] only if temperature less than 10°C rule.
*0 = Disabled (default)
*1 = Enabled, this line needs to be added in the [Station] section of the Cumulus.ini
Note that you need to set Cumulus to calculate the wind chill (if your station is a type that supplies one itself) for this setting to have any effect.
|-
|Logging=1
5,838