|EWmaxHourlyRain=999
|This is set in the settingsspike removal frame on the Calibration settings screen off the configuration menu. An hourly rain rate 'spike removal' filter for weather stations that do not supply rain rate so cumulus has to calculate it; ''changes in calculated value'' greater than the value specified here (set in calibration screen of configuration menu) will be ignored by Cumulus when it calculates the rain rate. Cumulus ignores this parameter for other makes of weather station that supply a rain rate to Cumulus.
|-
|EWmaxRainRate=999
|This is set in the settingsspike removal frame on the Calibration settings screen off the configuration menu. A rain rate 'spike removal' filter, ''changes in calculated value'' greater than the value specified here (set in calibration screen of configuration menu) will be ignored by Cumulus when it calculates the rain rate. Cumulus ignores this parameter for other makes of weather station that supply a rain rate to Cumulus.
|-
|EWgustdiff=999.0
|This is set in the settingsspike removal frame on the Calibration settings screen off the configuration menu. A wind gust 'spike removal' filter, ''changes in calculated value'' greater than the value specified here (set in calibration screen of configuration menu) will be ignored by Cumulus
|-
|EWwinddiff=999.0
|This is set in the settingsspike removal frame on the Calibration settings screen off the configuration menu.. A wind speed 'spike removal' filter, ''changes in calculated value'' greater than the value specified here (set in calibration screen of configuration menu) will be ignored by Cumulus
|-
|EWpressurediff=999.0
|This is set in the settingsspike removal frame on the Calibration settings screen off the configuration menu. A pressure change 'spike removal' filter, ''changes in read value'' from any station greater than the value specified here (set in calibration screen of configuration menu) will be ignored by Cumulus
|-
|EWTempdiff=999.0
|This is set in the settingsspike removal frame on the Calibration settings screen off the configuration menu. A temperature change 'spike removal' filter, ''changes in read value'' from any station greater than the value specified here (set in calibration screen of configuration menu) will be ignored by Cumulus. Replace 999.0 with the maximum difference in degrees C you are prepared to accept between successive data readings
|-
|EWhumiditydiff=999.0
|This is set in the settingsspike removal frame on the Calibration settings screen off the configuration menu. A humidity change 'spike removal' filter, ''changes in read value''from any station greater than the value specified here (set in calibration screen of configuration menu) will be ignored by Cumulus
|}
|