m (→Davis family specific:: added 'ForceVPBarUpdate') |
|||
|This parameter (attribute=value) is added directly to the file, it does not appear on a configuration screen.
The length of time in milliseconds which Cumulus waits to allow a response from the console to a command (i.e. a request for any kind of data) from an IP logger . Default is 500ms, see Cumulus MX forum where times up to 2000ms are suggested.
|-
|ForceVPBarUpdate=0
|VPrainGaugeType=▼
|This parameter (attribute=value) is added directly to the file, it does not appear on a configuration screen. The default (value=0) is to assume standard barometer updates on Davis stations. Set to 1, by adding ForceVPBarUpdate=1 in [Station] section to force more frequent barometer updates on Davis stations. Steve says "Having checked the code, I see it asks for 20 packets from the 'LOOP2' if the barometer forcing is on, otherwise it stops receiving LOOP data after 50 packets". Added in build 3042 (January 2017). Note that ForceVPBarUpdate=1 is only useful on very old versions of the console firmware.
|-
▲|VPrainGaugeType=0
|This parameter (attribute=value) is added directly to the file, it does not appear on a configuration screen. The default is to assume that people using MM units to display rain in Cumulus have a Metric Rain Adapter fitted to their rain gauge so it tips for every 0.2mm, and those selecting inches as their unit have the unmodified 0.01" rain gauge. This parameter over-rides that assumption, but note that conversion rounding errors will then occur.
|