|style="background:lightgray;"|[Offsets]
|style="background:lightgray;"|Section Name - the following 'attribute=value' parameters are the adjustment factors for your specific sensors
|-▼
|colspan="2" style="background:pink;"|Read-only parameters - The parameter listed below must be entered directly into file with Cumulus stopped. Used in both C1 and MX.
|-
|TempMult2=0.0 ▼
|This line needs to be added in the [Offsets] section of the Cumulus.ini, if it is omitted default multiplier is 0.0.▼
"Second order" multiplier by which measured outdoor Temperature is to be corrected, this means that the logged reading can be (TempMult2 X measured-temp X measured_temp) + (TempMult X measured_temp) + TempOffset▼
|-
|colspan="3" style="background:lightblue;"| Both Cumulus flavours
|TempMult=1
|First order multiplier by which measured outdoor Temperature is to be corrected (default=1).
For formula see
▲|-
▲|TempMult2=0.0
▲|This line needs to be added in the [Offsets] section of the Cumulus.ini, if it is omitted default multiplier is 0.0.
▲"Second order" multiplier by which measured outdoor Temperature is to be corrected, this means that the logged reading can be (TempMult2 X measured-temp X measured_temp) + (TempMult X measured_temp) + TempOffset
|-
|HumMult=1
|