Cumulus.ini (preserving history): Difference between revisions

From Cumulus Wiki
Jump to navigationJump to search
m
m (add category)
 
===Program General Options===
 
==Station Settings==
 
===Accessibility===
 
===General Settings - Station type and Log interval===
 
===General Settings - Log Rollover===
 
===General Settings - Units ===
 
===General Settings - Location===
 
===General Settings - Advanced Options===
 
===Station specific alternatives===
 
====Fine Offset Settings====
 
====Davis VP/VP2/Vue====
 
{{Template:WorkInProgressBanner}}
 
{| class="wikitable" border="1"
|-
!style="width:30px" | Parameter Line Entry
!style="width:60px" | Label on Settings page
!style="width:20px" | Default
!style="width:300px" | Description
|-
|style="background:lightgray;"|[Station]
|style="background:lightgray;"|Section name - the following parameters relate to the station configuration.
|-
|VP2SleepInterval=500
|This read-only parameter is the period which Cumulus waits between reads of the data from Davis stations, the value is in milliseconds. The default if the parameter has not been added manually to the file is 500 ms; if you suspect that data is being missed, you could add this parameter, manually reducing this figure. For VirtualVP users, tests revealed that VP2SleepInterval = 1100 seems to work the best. It updates every two seconds with few exceptions.
|-
|VPClosedownTime=x
| x is the number of seconds after the start of the re-connect attempts that you want the program to close itself
|-
|DavisCalcAltPress=1
|Davis stations calculate Sea Level Pressure from Station Pressure using a formula based on several parameters such as temperature, humidity, etc, rather than just using altitude as most other stations. CWOP require 'Altimeter Pressure' to be uploaded, i.e. a value calculated simply using altitude. '''Note for MX''', use of the LOOP2 interface means s.l.p. can be obtained from the Davis station.
 
If you don't use CWOP, or you are happy for Cumulus to send Sea-Level pressure to CWOP (the difference is small unless you are at high altitude), set this value to 0.
Cumulus will then use the Sea-Level Pressure value instead of the Cumulus calculated Altimeter Pressure.
*0 = Disabled
*1 = Enabled (default)
|-
|SyncDavisClock=0
|When set, at Cumulus start-up and at a fixed time (default 04:00, see next parameter) each day, Cumulus will set the Davis VP/VP2 clock to within a minute of the same time as the PC. (From build 3015 for MX).
*0 = Disabled, default (as deselected on the Station Configuration Screen)
*1 = Enabled, ensures that when Cumulus asks the station for data since time X, both recognise X!
|-
|ClockSettingHour=4
|Controls what hour of the day the SyncDavisClock activity will take place if it is enabled.
*4 = 04:00 (default value)
*0-23 = 00:00 to 23:00
|-
|VP2ConnectionType=1
|Weather station connection type
*0 = serial (see next parameter to specify COM port)
*(1 = usb - setting no longer available on screen, remains as default in cumulus.ini for those not using a Davis)
*2 = TCP/IP (see later parameters to specify ports)
Default is type 1, i.e. neither option on screen selected, so if you use a Davis you must select either serial or TCP/IP.
|-
|VP2TCPPort=22222
|Comunications port used if VP type has TCP/IP selected. Default is 2222
|-
|VP2IPAddr=0.0.0.0
|Weather station IP address if VP type has TCP/IP selected. Default is 0.0.0.0
|-
|VP2PeriodicDisconnectInterval=0
|When the clock minute changes, Cumulus stops the current stream of data from the console, disconnects, waits for the specified number of milliseconds, to allow the Weatherlink IP to briefly connect to the Davis Weatherlink site. Cumulus then attempts to reconnect.
 
Set it to zero to disable, if you are not using the Weatherlink site.
|-
|LogExtraSensors=0
|This is set in the '''Settings''' block on the Station settings screen off the configuration menu. Set this to 1 if you have additional sensors (e.g. a Davis Leaf Wetness probe) to make Cumulus read, display, and log the readings from the sensors. You don't select this for Solar/UV sensors.
|-
|UseDavisLoop2=1
|The current MX code uses ''LOOP2'' for two purposes. First, it uses the 'peak 10-minute gust' value, to avoid the problem where a gust might be missed, and secondly it uses the 'absolute pressure' value to make calculation of 'altimeter pressure' easier and more accurate. This is mainly used if you upload to CWOP.
*1 (default) = Cumulus MX will use the LOOP2 packet for Davis Weather Stations by default. The LOOP2 packet is supported on the VP2 with firmware version 1.90 or later, and on the Vue.
*0 = Select this if you have a Vantage Pro (i.e. the original 'VP1'), or a VP2 with pre-1.90 firmware, or if you are using Virtual VP, none of these support the LOOP2 packet.
 
Without this setting, Cumulus will revert to calculating the 10-minute gust value itself from the individual wind speed readings, but it will not currently attempt to calculate altimeter pressure correctly, it will simply use the sea-level pressure instead. This is likely to be an issue if you are at high altitude and you upload to CWOP using Cumulus MX.
|-
|DavisIPResponseTime=500
|The length of time in milliseconds which Cumulus waits to allow a response from the console to a command (i.e. a request for any kind of data) from an IP logger . Default is 500ms, see Cumulus MX forum where times up to 2000ms are suggested.
|-
|ForceVPBarUpdate=0
| Added in build 3042 (January 2017).
 
The default (value=0) is to assume standard barometer updates on Davis stations. Set to 1, by adding ForceVPBarUpdate=1 in [Station] section to force more frequent barometer updates on Davis stations. Steve says "Having checked the code, I see it asks for 20 packets from the 'LOOP2' if the barometer forcing is on, otherwise it stops receiving LOOP data after 50 packets". Note that ForceVPBarUpdate=1 is only useful on very old versions of the console firmware.
|-
|DavisIncrementPressureDP=0
|(from version 3.0.0 build 3042) A Cumulus.ini setting to turn off the 'extra' decimal place in pressure values on Davis stations. To limit the pressure to 1 decimal for mb/hPa and 2 for inHg, add this to the [Station] section
|-
|VPrainGaugeType=0
|The default is to assume that people using MM units to display rain in Cumulus have a Metric Rain Adapter fitted to their rain gauge so it tips for every 0.2mm, and those selecting inches as their unit have the unmodified 0.01" rain gauge. This parameter over-rides that assumption, but note that conversion rounding errors will then occur.
 
Specifies the units selected on your Vantage Pro Rain Gauge. Set to 0 for a 0.2mm gauge and 1 for a 0.01" gauge.
|-
|DataLogging=0
|(Build 3018 onwards). Default is 0, change to 1 for more detailed Davis logging.
*0 (default) = Cumulus MX will not add extra logging.
*1 = To add extra logging to the diags file for data received from Davis stations. Use this with care, the log will get very large.
I've also added some more diagnostics to try to find the cause of the problem where data stops being read from Davis stations. Debug logging is required to be turned on. (Build 3022 onwards).|-
|-
|AutoUpdateIpAddress=1
|default = 1, set to 0 to switch off the WLL autodetection of IP address. This is a workaround for a WLL firmware bug that does not update the IP address when it changes using DHCP.
|-
|ZeroConfig
|set this on station settings screen; to enable/disable the entry/update of the stations IP address via auto-discovery
|}
 
====WM918/WMR928 Settings====
 
Oregon Scientific specific
{{Template:WorkInProgressBanner}}
 
{| class="wikitable" border="1"
|-
!style="width:30px" | Parameter Line Entry
!style="width:60px" | Label on Settings page
!style="width:20px" | Default
!style="width:300px" | Description
|-
|style="background:lightgray;"|[Station]
|style="background:lightgray;"|Section name - the following parameters relate to the station configuration.
|-
|Humidity98Fix=0
|Applies to weather station types that never report more than 98% relative humidity.
*0 = Disabled (default)
*1 = Enabled, humidity displayed and recorded as 100% if your sensor registers a relative humidity of 98% or greater. Normally only useful for Oregon Scientific stations.
|-
|LogExtraSensors=0
|This setting determines whether MX looks for readings from extra temperature probes etc.
*0=Disabled (default)
*1= Enabled - Used for Oregon Scientific WMR-928 and similar stations if you have additional sensors (e.g. another temperature probe) to make Cumulus read, display, and log the readings from those sensors. You don't use this for Solar/UV sensors.
(Note this attribute appears in [[#Davis_family_specific|Davis family]] and [[#Introduced_for_problems_with_Fine_Offset_family:|Fine Offset family]] tables above and in [[#Instromet_station_specific:|Instromet station specific:]] table below with different usage explanations).
|-
|colspan="2" style="background:pink;"|Read-only parameters - how to set depends on your MX release.
|-
|WMR928TempChannel=N
|for WMR-928 stations (and other serial stations using the same protocol, eg WMR-968) to use an 'extra' channel (see previous parameter) as your main temperature sensor, set N to the required channel
|-
|WMR200TempChannel=N
|for WMR200 stations (and any other Oregon Scientific USB stations which work with Cumulus, e.g. WMR100) to use an 'extra' channel as your main temperature sensor, set N to the required channel
|}
 
 
====EasyWeather File Settings====
 
====Instromet Settings====
 
 
{{Template:WorkInProgressBanner}}
 
{| class="wikitable" border="1"
|-
!style="width:30px" | Parameter Line Entry
!style="width:60px" | Label on Settings page
!style="width:20px" | Default
!style="width:300px" | Description
|-
|style="background:lightgray;"|[Station]
|style="background:lightgray;"|Section name - the following parameters relate to the station configuration.
|-
|ImetWaitTime=200
|This parameter (attribute=value) if you need to change it from its '''default of 200 ms''' is added directly to the file, it does not appear on a configuration screen.
Specifies the time in milliseconds that Cumulus allows for a response from an Instromet station. If you are having problems with reading from an Instromet station, try inserting this line into the ''Station'' section using a value of 500. According to the specification, 500 ms is the absolute maximum time that the station should take to respond to any command.
|-
|ImetBaudRate=19200
|The default value is 19200. Some ?older? Instromet loggers operate at 115200, if you have one of these older loggers you will need to reset this value
|-
|SyncDavisClock=0
|Note despite the name of the parameter within 'Cumulus.ini', this does apply to Instromet stations.
When set, at Cumulus start-up and at 04:00 each day, Cumulus will set the Instromet clock to within a minute of the same time as the PC
*0 = Disabled, default as deselected on the Station Configuration Screen
*1 = Enabled, ensures that when Cumulus asks the station for data since time X, both recognise X as representing same time!
|-
|LogExtraSensors=0
|If you have 'extra sensors' selected, the wet bulb reading will be used as an extra temperature sensor. Otherwise it is used as 'wet bulb' and the humidity will be calculated from that and the dry bulb sensor.
*0=Disabled (default). For a wet bulb sensor, Cumulus will output the humidity, not the temperature shown by the wet bulb.
*1= Enabled - Used for optional Sunshine hours or extra temperature sensors on Instromet stations. For a wet bulb sensor, Cumulus will output the temperature it shows, but not calculate the humidity.
|}
 
====Davis WeatherLink Live====
 
{{Template:WorkInProgressBanner}}
 
{| class="wikitable" border="1"
|-
!style="width:30px" | Parameter Line Entry
!style="width:60px" | Label on Settings page
!style="width:20px" | Default
!style="width:300px" | Description
|-
 
====Ecowittt GW1000 Settings====
 
{{Template:WorkInProgressBanner}}
 
Ecowitt GW1000 and Froggit DP1500 (and any equivalents) specific
{| class="wikitable" border="1"
|-
!style="width:30px" | Parameter Line Entry
!style="width:60px" | Label on Settings page
!style="width:20px" | Default
!style="width:300px" | Description
|-
|IPAddress=
|There is no default value, stores the IP address of your GW1000 WiFi logger, set via the station settings page.
|}
 
====Solar====
 
{| class="wikitable" border="1"
|-
!style="width:150px" | Parameter Line Entry
!style="width:600px" | Function
|-
|style="background:lightgray;"|[Solar]
|style="background:lightgray;"|Section Name - the following parameters are set as described above
|-
|SunThreshold=75
|If you have a solar sensor: Cumulus tries to determine whether the sun is shining by determining whether the current solar radiation value is above a certain percentage of the current theoretical maximum. The value you supply here is used as that percentage. The default value is 75%.
|-
|RStransfactor=0.8
|Cumulus uses the Ryan-Stolzenbach formula to determine the current theoretical maximum solar radiation at your location at the current moment in time. This formula has a factor to allow for the transmission of the radiation through the atmosphere; the default is 0.80.
|-
|SolarMinimum=0
|This setting allows you to specify a minimum solar radiation value which needs to be reached before it can be considered to be sunny. Note that this setting does not replace the calculation using the current theoretical maximum, it specifies an additional condition which has to be met. This setting therefore allows you to cater for the periods at the beginning and end of the day when the theoretical maximum is very low.
|-
|LuxToWM2=0.0079
|this parameter applies if you have a Fine Offset station with a solar detector. These supply 'Lux' values rather than 'W/m2' values that Davis stations supply. Cumulus attempts to convert from Lux to W/m2 using the supplied multiplication factor. You can add this parameter if you want to use a value other than the default of 0.0079, which is the generally accepted standard conversion factor for sunlight.
|-
|UseBlakeLarsen=0
| Called B/l on screen. Set this to 1 if you have a Blake-Larsen Sun Recorder, and you want Cumulus to get today's sunshine hours from it. You need to configure the Blake-Larsen software to put the SRsunshine.dat file into the correct folder i.e. the ''' program root folder''' in MX (i.e. same folder as where "Cumulus.ini" is stored).
|-
|SolarCalc=1
|The value is set in the MX user interface when the solar calculation method is set.
*0 (default) = Ryan-Stolzenbach calculation, which uses the RStransfactor entry to tune the output.
*1 = Bras calculation, which uses the BrasTurbidity entry below to tune the output.
|-
|BrasTurbidity=2.0
|The value is set in the MX user interface when the solar calculation method is set.
*2.0 (default) = Perfect clear sky
*decimal value = The normal range is 2 (Clear sky) to 5 (Smoggy)
|}
 
 
===Common Options===
 
===Forecast===
 
===Annual Rainfall===
 
===Growing Degree Days===
 
===Annual Temperature Sum===
 
===Graphs===
 
===Display Options===
 
==Internet Settings==
 
===Web/FTP Site===
 
===Web/FTP Settings===
 
===Email Server Settings===
 
===External Programs===
 
===MQTT===
 
MQTT (Message Queuing Telemetry Transport) is a machine-to-machine (M2M), also known as "Internet of Things", connectivity protocol.
 
This section was introduced by release 3.5.0 (build 3071)
 
{| class="wikitable" border="1"
|-
!style="width:150px" | Parameter Line Entry
!style="width:600px" | Function
!style="width:150px" | Where to Edit
|-
|style="background:lightgray;"|[MQTT]
|style="background:lightgray;"|Cumulus.ini Section Name
|style="background:lightgray;"|Settings Section Name
|-
|Server=
|Note there is no default. This text box is to enter your server name or the IPv4 or IPv6 address to find your server
|MQTT section
|-
|Username=
|This is optional.This text box is to enter the username if one is needed for updating your server
|MQTT section
|-
|Password=
|This is optional. This text box is to enter any password needed for that username
|MQTT section
|-
|Port=1883
|Note default. To edit which port is used to connect to your server
|MQTT section
|-
|UseTLS=0
|Transport Layer Security (TLS), and its now-deprecated predecessor, Secure Sockets Layer (SSL), are cryptographic protocols designed to provide communications security over a computer network. This tick box on settings screen indicates whether TLS support is required,
*default is not (0),
*set to 1 if modern security protocol is being used
|MQTT section tick box
|-
|IPversion=0
|Mandatory - This parameter must be added to this Cumulus.ini section, it cannot be edited on a screen.
*0=default,
*4=IPv4,
*6=IPv6
|In file only
|-
|EnableDataUpdate=0
|This provides an easy way to stop/start the updating without losing other settings. Default is unticked as most people do not use this functionality.
|tick box in '''Send message on data update''' section
|-
|UpdateTopic=CumulusMX/DataUpdate
|This feature in the '''Send message on data update''' section is where you specify the name to give to the update message
|'''Send message on data update''' section
|-
|UpdateTemplate=DataUpdateTemplate.txt
|In the CumulusMX/mqtt folder there is a default template with a file name specified by the default value of this parameter. In that default file <tt>{"time":"<#timehhmmss>","windspeed":<#wlatest rc=y>,"winddir":<#bearing>}</tt> will send wind readings in case for example you want to close something when it is windy. If you create your own file, you can put its name here.
|'''Send message on data update''' section
|-
|EnableInterval=0
|This tick box provides an easy way to stop/start this type of updating without losing other settings. Default is unticked as most people do not use this functionality.
|tick box in '''Send message at fixed intervals''' section
|-
|IntervalTime=600
|This text box is where you enter the time between messages in seconds, the default is 600 meaning every ten minutes.
|'''Send message at fixed intervals''' section
|-
|IntervalTopic=CumulusMX/Interval
|This text box is where you specify the name to give to the fixed interval update message
|'''Send message at fixed intervals''' section
|-
|IntervalTemplate=IntervalTemplate.txt
|In the CumulusMX/mqtt folder there is a default template with a file name specified by the default value of this parameter. In that default file <tt>{"time":"<#timehhmmss>","temp":<#temp rc=y>,"humidity":<#hum>}</tt> will send temperature and humidity readings in case for example you want to open something when it feels uncomfortable. If you create your own file, you can put its name here.
|'''Send message at fixed intervals''' section
|}
 
 
===Moon Image===
 
===Proxies===
 
Cumulus 1.9.4 beta build 1061 introduces these. Currently, search the forum using the term 'proxies' for more details. They will be described here when 1.9.4 becomes a full release, currently they are being tested.
 
HTTPProxyName=
 
HTTPProxyPort=
 
HTTPProxyUser=
 
HTTPProxyPassword=
 
 
 
 
 
 
 
[[Category:Cumulus Files]]
5,838

edits

Navigation menu