|style="background:lightgray;"|Section name - the following parameters relate to the station configuration.
|-
|Humidity98Fix=0
|
|0 (disable)
|Applies to weather station types that never report more than 98% relative humidity.
*0 = Disabled (default)
*1 = Enabled, humidity displayed and recorded as 100% if your sensor registers a relative humidity of 98%
|-
|LogExtraSensors=0
|
|0 (disable)
|This setting determines whether MX looks for readings from extra temperature probes etc.
*0=Disabled (default)
*1= Enabled - Used for Oregon Scientific WMR-928 and similar stations if you have additional sensors (e.g. another temperature probe) to make Cumulus read, display, and log the readings from those sensors. You don't use this for Solar/UV sensors..
▲|-
|-
|WMR928TempChannel=N
|
|(no default)
|for WMR-928 stations (and other serial stations using the same protocol, eg WMR-968) to use an 'extra' channel (see previous parameter) as your main temperature sensor, set N to the required channel
|-
|WMR200TempChannel=N
|
(no default)
|for WMR200 stations (and any other Oregon Scientific USB stations which work with Cumulus, e.g. WMR100) to use an 'extra' channel as your main temperature sensor, set N to the required channel
|}