* Tick (value shown as 1 in Cumulus.ini) then Cumulus will calculate dew point from temperature and humidity supplied by station
* Don't tick (value shown as 0 in Cumulus.ini) action depends on '''Calibration settings'''
** If Cumulus has non-default multiplier and/or offset settings for temperature or humidity, Cumulus will calculate dew-point. This avoids the restriction in the Oregon Scientific stations where the dew point can never be below freezing point.
** If station provides dew point, then that will be used provided no multiplier/offsets have been specified for temperature or humidity
|-
** If Cumulus has non-default multiplier and/or offset settings for temperature or wind speed, Cumulus will calculate wind chill
** If station provides wind chill, then that will be used provided no multiplier/offsets have been specified for temperature or wind speed
Note that some stations (Fine Offset, for example), do not make a wind chill value available to Cumulus. For these, Cumulus always calculates it.
|-