5,838
edits
m (typo) |
m (Oregon Scientific WM918/WMR928 Settings update) |
||
<big>Please note this page was created 13 June 2021.
At last update, it shows position as at beta build 3135, (missing some changes for the 3.12.0 release build of 3141).
This new page was created to reflect parameters added to Cumulus.ini in releases 3.8.0, 3.9.2, 3.10.0, and 3.12.0 (early beta builds - June 2021). It excludes all parameters removed after release 3.7.0.</big>
It is assumed that [[Cumulus.ini_(Cumulus_1)#La_Crosse_specific:|most parameters remain same]]
===Oregon Scientific WM918/WMR928 Settings===
The Oregon Scientific code has not changed since the earliest beta MX (3.0.0) builds based on moving compiled code from Cumulus 1.
* Introduced for legacy Cumulus▼
It appears very few current Cumulus users own these obsolete models, so all these settings have to be added directly into the file, you can't edit them in the admin interface, and they will be missing from any configuration file created by any MX release.
▲* Introduced for legacy Cumulus, and unchanged by MX
* File Section is [Station], these settings need to be manually entered into file below that section heading
{| class="wikitable" border="1"
|-
!style="width:30px" | Parameter Line Entry
!style="width:100px" |
!style="width:20px" | Default
!style="width:300px" | Description
|-
|Humidity98Fix=0
| Stop MX and add this into file
|0 (disable)
|Applies to weather station types that never report more than 98% relative humidity.
|-
|LogExtraSensors=0
| Stop MX and add this into file
|0 (disable)
|This setting determines whether MX looks for readings from extra temperature probes etc.
|-
|WMR928TempChannel=N
| Stop MX and add this into file
|(
|for WMR-928 stations (and other serial stations using the same protocol, eg WMR-968) to use an 'extra' channel (see previous parameter) as your main temperature sensor, set N to the required channel
|-
|WMR200TempChannel=N
| Stop MX and add this into file
|(
|for WMR200 stations (and any other Oregon Scientific USB stations which work with Cumulus, e.g. WMR100) to use an 'extra' channel as your main temperature sensor, set N to the required channel
|}
|
edits