|CalculatedDP=0
|Selected on same screen as other parameters. Simple tick or not:
* Tick (value shown as 1 in Cumulus.ini) then Cumulus will calculate wind chill from temperature and wind speed
*0 = Disabled, Cumulus will display the dew point value supplied by the station.
** Note that there is a maximum temperature, and minimum wind speed, for Cumulus to make the calculation, see [[Wind_chill]] page
*1 = Enabled, Cumulus will calculate the dew point instead. This avoids the restriction in the Oregon Scientific stations where the dew point can never be below freezing point.
* Don't tick (value shown as 0 in Cumulus.ini) action depends on '''Calibration settings'''
*1* =If Cumulus has non-default multiplier and/or offset settings for temperature or wind Enabledspeed, Cumulus will calculate the dew pointwind insteadchill. This avoids the restriction in the Oregon Scientific stations where the dew point can never be below freezing point.
** If station provides wind chill, then that will be used provided no multiplier/offsets have been specified for temperature or wind speed
|-
|CalculatedWC=0
|Selected on same screen as other parameters. Available only from version 1.8.3. Simple tick or not:
* Tick (value shown as 1 in Cumulus.ini) then Cumulus will calculate wind chill from temperature and wind speed
*0 = Disabled
** Note that there is a maximum temperature, and minimum wind speed, for Cumulus to make the calculation, see [[Wind_chill]] page
*1 = Enabled, Cumulus will calculate the wind chill instead of using the value supplied by the station. You should set this if you have specified any calibration values for wind and/or temperature, so that Cumulus can also apply those adjustments to the wind chill.
* Don't tick (value shown as 0 in Cumulus.ini) action depends on '''Calibration settings'''
** If Cumulus has non-default multiplier and/or offset settings for temperature or wind speed, Cumulus will calculate wind chill
** If station provides wind chill, then that will be used provided no multiplier/offsets have been specified for temperature or wind speed
Note that some stations (Fine Offset, for example), do not make a wind chill value available to Cumulus. For these, Cumulus always calculates it.
|-
'''You should not select the previous parameter 'ConfirmClose' if you use this option.'''
|}
 
 
==== Spike Removal ====
5,838