You may have a thermostat that makes your heating come on when the temperature falls below a threshold.
You may have a thermostat that makes your heating come on when the temperature falls below a threshold.
Cumulus calculates the time that the temperature is below that threshold and reports it as 'Heat degree days' using the unit of ''days''. Cumulus reports this by month as part of the NOAA report. It also appears in the annual NOAA report.
Cumulus calculates an integration of the number of degrees below the threshold over the time that the temperature is below that threshold.


Cumulus reports this by month as part of the National Oceanic and Atmospheric Administration (NOAA) style report, in the annual NOAA report, in dayfile.txt, and via heating degree days web tag. (NOAA is an Operating Unit of the U.S. Department of Commerce).
So if for each day of November, there was just one hour below the threshold, the total for the month would be 30 hours reported as 1.5 days.

So if for the whole of November, there was just one hour at one degree below the threshold, two hours at five degrees below, and three hours at seven degrees below; the total for the month would be (1*1)+(2*5) +(3*7) hours reported as 32 degree days.
==Chill Hours==
==Chill Hours==
A related measure, also reported by Cumulus counting the ''hours'' below a (different) configurable temperature threshold for the 12 month period starting on the 1st day of a configurable month, is Chill Hours.
A related measure, also reported by Cumulus counting the ''hours'' below a (different) configurable temperature threshold for the 12 month period starting on the 1st day of a configurable month, is Chill Hours.


The traditional way of calculating the accumulation of Chill Hours is the number of hours the temperature is below 45F or 7.5C for the period of 1st October to 30th April in the Northern Hemisphere. This is available on Cumulus as that threshold, and start date are the default, so you simply observe the reported value on 30 April.
The traditional way of calculating the accumulation of Chill Hours is the number of hours the temperature is below 45F or 7.5C for the period of 1st October to 30th April in the Northern Hemisphere. On Cumulus that threshold, and start date are the default, so you simply observe the reported value on 30 April. The current figure is viewable on the 'This Year' screen accessed from the View menu, and is available via web tag <#chillhours> to be added to a web page template of your design.


The main applicability is to stone and seed fruit as their exposure to low temperatures during the winter months will have a significant effect on the following harvest. Too few cold hours can result in poor quality and quantity of the crop. Fruit tree varieties prefer a Chill Hour rating from below 200 hours to around 1500 hours.
The main applicability is to stone and seed fruit as their exposure to low temperatures during the winter months will have a significant effect on the following harvest. Too few cold hours can result in poor quality and quantity of the crop. Fruit tree varieties prefer a Chill Hour rating from below 200 hours to around 1500 hours.
Line 14: Line 16:
However, the way it can be configured on Cumulus will allow you to track air frost hours, ground frost hours or any other below the threshold parameter.
However, the way it can be configured on Cumulus will allow you to track air frost hours, ground frost hours or any other below the threshold parameter.


[[User:Sfws|Sfws]] 10:53, 1 December 2012 (UTC) (with thanks to Randy who raised Enhancement Request #117 and supplied some of the above text)
==Cold Degree Days==
==Cold Degree Days==
You may have a thermostat that makes a cooling system come on when the temperature rises above a threshold.
You may have a thermostat that makes a cooling system come on when the temperature rises above a threshold.

Cumulus calculates the time that the temperature is above that threshold and reports it as 'Cold degree days' using the unit of days.
So if for each day of June, there were 3 hours above the threshold, the total for the month would be 90 hours reported as 3 days.
Cumulus calculates an integration of the number of degrees above the threshold over the time that the temperature is above that threshold.

Cumulus reports this by month as part of the NOAA report, in the annual NOAA report, in dayfile.txt, and via cooling degree days web tag.

So if for one day in June, successive readings at one minute intervals above the threshold were 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, then it stayed 10 degrees above for 1 hour, before falling in successive minutes to 9, 8, 7, 6, 5, 4, 3, 2, and 1 degrees above the threshold, the total for that day (of 1440 minutes) would be 150 degree minutes reported as 150/1440 or 0.1 degree days.
<br>
[[User:Sfws|Sfws]] 10:53, 1 December 2012 (UTC) (with thanks to Mark Crossley for help with understanding ''degree day'' unit)

=Setting the threshold=
=Setting the threshold=
[[File:NOAA_Setup_extract.jpg‎]]The thresholds for '''Heat and Cold Degree days''' are set in the ''NOAA Setup'' option within the ''Configuration'' menu. The picture shows just parts of the setup screen. It allows you to specify the two thresholds in the units you have selected to use in your implementation of Cumulus. Cumulus stores your selected threshold values in '''Cumulus\Cumulus.ini''', Heating and Cooling Degree Days are stored in dayfile.txt, and are available via heating/cooling degree days web tags.
[[File:NOAA_Setup_extract.jpg‎]]The thresholds for '''Heat and Cold Degree days''' are set in the ''NOAA Setup'' option within the ''Configuration'' menu. The picture shows just parts of the setup screen. It allows you to specify the two thresholds in the units you have selected to use in your implementation of Cumulus. Cumulus stores your selected threshold values in the [NOAA] section in '''Cumulus\Cumulus.ini'''.


CAUTION: Think carefully, about what threshold to use. If you later change the threshold, only subsequent calculations use the new threshold. All retrospective calculations remain based on the old threshold, so values shown on a NOAA report for a month or a year with a threshold change will be rubbish, and need to be manually recalculated. The figures are on the reports, so make any edits directly on past reports.
CAUTION: Think carefully, about what threshold to use. If you later change the threshold, only subsequent calculations use the new threshold. All past calculations were based on the old threshold, so values shown on a NOAA report for a month or a year with a threshold change will be rubbish (the new threshold is shown on the report, but it has not been applied retrospectively), and need to be manually recalculated making any consequent edits directly on past reports.


The '''Chill Hours defaults''' are configurable by adding entries to the [Station] section in Cumulus.ini:
The '''Chill Hours defaults''' are configurable by adding entries to the [Station] section in Cumulus.ini:


ChillHourSeasonStart=10
''ChillHourSeasonStart=10''


ChillHourThreshold=45
''ChillHourThreshold=45''


The season start figure is the month number, and the temperature threshold is specified in the units that you use in Cumulus.
The season start figure is the month number, and the temperature threshold is specified in the units that you use in Cumulus.

The current figure is viewable on the 'This Year' screen, and is available via web tag <#chillhours>


[[Category:Terminology]]
[[Category:Terminology]]
<br>
[[User:Sfws|Sfws]] 07:42, 29 November 2012 (UTC)

Revision as of 10:53, 1 December 2012

Explanation

Heat Degree Days

You may have a thermostat that makes your heating come on when the temperature falls below a threshold. Cumulus calculates an integration of the number of degrees below the threshold over the time that the temperature is below that threshold.

Cumulus reports this by month as part of the National Oceanic and Atmospheric Administration (NOAA) style report, in the annual NOAA report, in dayfile.txt, and via heating degree days web tag. (NOAA is an Operating Unit of the U.S. Department of Commerce).

So if for the whole of November, there was just one hour at one degree below the threshold, two hours at five degrees below, and three hours at seven degrees below; the total for the month would be (1*1)+(2*5) +(3*7) hours reported as 32 degree days.

Chill Hours

A related measure, also reported by Cumulus counting the hours below a (different) configurable temperature threshold for the 12 month period starting on the 1st day of a configurable month, is Chill Hours.

The traditional way of calculating the accumulation of Chill Hours is the number of hours the temperature is below 45F or 7.5C for the period of 1st October to 30th April in the Northern Hemisphere. On Cumulus that threshold, and start date are the default, so you simply observe the reported value on 30 April. The current figure is viewable on the 'This Year' screen accessed from the View menu, and is available via web tag <#chillhours> to be added to a web page template of your design.

The main applicability is to stone and seed fruit as their exposure to low temperatures during the winter months will have a significant effect on the following harvest. Too few cold hours can result in poor quality and quantity of the crop. Fruit tree varieties prefer a Chill Hour rating from below 200 hours to around 1500 hours.

However, the way it can be configured on Cumulus will allow you to track air frost hours, ground frost hours or any other below the threshold parameter.

Sfws 10:53, 1 December 2012 (UTC) (with thanks to Randy who raised Enhancement Request #117 and supplied some of the above text)

Cold Degree Days

You may have a thermostat that makes a cooling system come on when the temperature rises above a threshold.

Cumulus calculates an integration of the number of degrees above the threshold over the time that the temperature is above that threshold.

Cumulus reports this by month as part of the NOAA report, in the annual NOAA report, in dayfile.txt, and via cooling degree days web tag.

So if for one day in June, successive readings at one minute intervals above the threshold were 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, then it stayed 10 degrees above for 1 hour, before falling in successive minutes to 9, 8, 7, 6, 5, 4, 3, 2, and 1 degrees above the threshold, the total for that day (of 1440 minutes) would be 150 degree minutes reported as 150/1440 or 0.1 degree days.
Sfws 10:53, 1 December 2012 (UTC) (with thanks to Mark Crossley for help with understanding degree day unit)

Setting the threshold

NOAA Setup extract.jpgThe thresholds for Heat and Cold Degree days are set in the NOAA Setup option within the Configuration menu. The picture shows just parts of the setup screen. It allows you to specify the two thresholds in the units you have selected to use in your implementation of Cumulus. Cumulus stores your selected threshold values in the [NOAA] section in Cumulus\Cumulus.ini.

CAUTION: Think carefully, about what threshold to use. If you later change the threshold, only subsequent calculations use the new threshold. All past calculations were based on the old threshold, so values shown on a NOAA report for a month or a year with a threshold change will be rubbish (the new threshold is shown on the report, but it has not been applied retrospectively), and need to be manually recalculated making any consequent edits directly on past reports.

The Chill Hours defaults are configurable by adding entries to the [Station] section in Cumulus.ini:

ChillHourSeasonStart=10

ChillHourThreshold=45

The season start figure is the month number, and the temperature threshold is specified in the units that you use in Cumulus.