Cumulus.ini (preserving history): Difference between revisions

m
|style="background:lightgray;"|Section name - the following parameters relate to the station configuration.
|-
|colspan="2" style="background:pink;"|Read-only parameters - The parameters listed below must be entered directly into file with Cumulus stopped. Used in both C1 and MX unless indicated.
|RestartIfUnplugged=0
|{{Version badge 1}}This is set in the settings frame on the Station settings screen off the configuration menu.
*0 = Disabled, default i.e. deselected on the Station Configuration Screen
*1 = Enabled, Cumulus will restart if it detects that a Fine Offset station is unplugged. '''Note:''' Unless the station has been manually plugged in again, a Cumulus restart has no benefit; normally the station should be checked to be plugged in before Cumulus is ever started and the station then left plugged in.
 
Not applicable to MX
|-
|SyncFOReads=0
|This is set in the settings frame on the Station settings screen off the configuration menu.
*0 = Synchronisation disabled, default (Cumulus reads the memory without taking into account when memory is being updated)
*1 = Re-synchronizes once each day, to avoid reading memory at time of memory update
A Fine Offset station will be writing to its memory every 48 or 60 seconds (depending on model); Cumulus can attempt once a day to identify when this update of memory occurs, and thereafter try not to read the memory at update time, by using what is called a synchronisation mode of operation. See next parameter.
 
Cumulus 1 and MX
|-
|FOReadAvoidPeriod=3
 
Tell Cumulus what offset to use, by using an external text editor to insert this parameter where x.y is your pressure offset in in mb or hPa [i.e. your station (absolute) pressure subtracted from the sea-level (relative) pressure]. Applies to Cumulus 1 and MX.
|-
|RestartIfUnplugged=0
|{{Version badge 1}}This is set in the settings frame on the Station settings screen off the configuration menu.
*0 = Disabled, default i.e. deselected on the Station Configuration Screen
*1 = Enabled, Cumulus will restart if it detects that a Fine Offset station is unplugged. '''Note:''' Unless the station has been manually plugged in again, a Cumulus restart has no benefit; normally the station should be checked to be plugged in before Cumulus is ever started and the station then left plugged in.
 
Not applicable to MX
|-
|SyncFOReads=0
|This is set in the settings frame on the Station settings screen off the configuration menu.
*0 = Synchronisation disabled, default (Cumulus reads the memory without taking into account when memory is being updated)
*1 = Re-synchronizes once each day, to avoid reading memory at time of memory update
A Fine Offset station will be writing to its memory every 48 or 60 seconds (depending on model); Cumulus can attempt once a day to identify when this update of memory occurs, and thereafter try not to read the memory at update time, by using what is called a synchronisation mode of operation. See next parameter.
 