Cumulus.ini (preserving history): Difference between revisions

m
|style="background:lightgray;"|[Offsets]
|style="background:lightgray;"|Section Name - the following 'attribute=value' parameters are the adjustment factors for your specific sensors
|-
|colspan="2" style="background:pink;"|Read-only parameters - The parameter listed below must be entered directly into file with Cumulus stopped. Used in both C1 and MX.
|-
|TempMult2=0.0
|This line needs to be added in the [Offsets] section of the Cumulus.ini, if it is omitted default multiplier is 0.0.
"Second order" multiplier by which measured outdoor Temperature is to be corrected, this means that the logged reading can be (TempMult2 X measured-temp X measured_temp) + (TempMult X measured_temp) + TempOffset
|-
|colspan="3" style="background:lightblue;"| Both Cumulus flavours
|TempMult=1
|First order multiplier by which measured outdoor Temperature is to be corrected (default=1).
For formula see nextread-only item.
|-
|TempMult2=0.0
|This line needs to be added in the [Offsets] section of the Cumulus.ini, if it is omitted default multiplier is 0.0.
"Second order" multiplier by which measured outdoor Temperature is to be corrected, this means that the logged reading can be (TempMult2 X measured-temp X measured_temp) + (TempMult X measured_temp) + TempOffset
|-
|HumMult=1
5,838