Cumulus.ini (preserving history): Difference between revisions

m
→‎Section: Station: Moving new parameter "RecordSetTimeoutHrs" wrongly inserted into "Cumulus 1 and MX" sub-section into correct "Cumulus MX only" sub-section
m (→‎Section: Station: Moving new parameter "RecordSetTimeoutHrs" wrongly inserted into "Cumulus 1 and MX" sub-section into correct "Cumulus MX only" sub-section)
* 0 = Sensor check enabled (default)
* 1 = Sensor check disabled
|-
|SpecialLog=0
|[[File:Badge vMx.png]] Not available in MX
 
{{Version badge 1}}In Cumulus 1 there is an option of whether to record temperature and humidity (both indoor and outside values) in a log:
* 0 (default) = no special log
* 1 = Add this entry to start updating a file called 'speciallog.txt' in the data folder with the following fields:
 
date(dd/mm/yy),time(hh:mm),inside temp,inside humidity,inside dew point,outside temp,outside humidity,outside dew point
 
See [https://cumulus.hosiene.co.uk/viewtopic.php?f=5&t=15040 forum]
|-
|colspan="2" style="background:lightblue;"| Both Cumulus flavours - in MX edit in Station Settings, for Cumulus 1 edit in Station Configuration Screen
 
[[File:Badge vMx.png]] - this does not appear in the station settings, stop MX, and add it directly into Cumulus.ini within this [Station] section.
|-
|RecordSetTimeoutHrs=24
|[[File:Badge vMx.png]]Available in MX version 3.5.1 onwards only, allows the time from when a record is set to when it is cleared to be varied. The web tags: TempRecordSet, WindRecordSet, RainRecordSet, HumidityRecordSet, PressureRecordSet, HighTempRecordSet,LowTempRecordSet, HighAppTempRecordSet, LowAppTempRecordSet, HighHeatIndexRecordSet, LowWindChillRecordSet, HighMinTempRecordSet, LowMaxTempRecordSet, HighDewPointRecordSet, LowDewPointRecordSet, HighWindGustRecordSet, HighWindSpeedRecordSet, HighRainRateRecordSet,HighHourlyRainRecordSet, HighDailyRainRecordSet, HighMonthlyRainRecordSet, HighhHumidityRecordSet, HighWindrunRecordSet, LowHumidityRecordSet, HighPressureRecordSet, LowPressureRecordSet, LongestDryPeriodRecordSet, LongestWetPeriodRecordSet, HighTempRangeRecordSet, LowTempRangeRecordSet will all return 1 from when relevant record is set for the period of time set here (default 24 hours) and then reset to 0.
|-
|Latitude=0
 
[[File:Badge vMx.png]] This parameter is ignored by MX, best to remove it, MX uses a Comport parameter instead, see [[#Parameters_changed|#Parameters_changed section]] above.
|-
|SpecialLog=0
|[[File:Badge vMx.png]] Not available in MX
 
{{Version badge 1}}In Cumulus 1 there is an option of whether to record temperature and humidity (both indoor and outside values) in a log:
* 0 (default) = no special log
* 1 = Add this entry to start updating a file called 'speciallog.txt' in the data folder with the following fields:
 
date(dd/mm/yy),time(hh:mm),inside temp,inside humidity,inside dew point,outside temp,outside humidity,outside dew point
 
See [https://cumulus.hosiene.co.uk/viewtopic.php?f=5&t=15040 forum]
|-
|colspan="2" style="background:lightblue;"| Cumulus MX only
|Logging=0
|This parameter can be edited in the file or in station settings or by use of a parameter when starting MX. It controls whether MX stores extra diagnostic information about its interaction with the weather station.
|-
|RecordSetTimeoutHrs=24
|[[File:Badge vMx.png]]Available in MX version 3.5.1 onwards only, allows the time from when a record is set to when it is cleared to be varied. The web tags: TempRecordSet, WindRecordSet, RainRecordSet, HumidityRecordSet, PressureRecordSet, HighTempRecordSet,LowTempRecordSet, HighAppTempRecordSet, LowAppTempRecordSet, HighHeatIndexRecordSet, LowWindChillRecordSet, HighMinTempRecordSet, LowMaxTempRecordSet, HighDewPointRecordSet, LowDewPointRecordSet, HighWindGustRecordSet, HighWindSpeedRecordSet, HighRainRateRecordSet,HighHourlyRainRecordSet, HighDailyRainRecordSet, HighMonthlyRainRecordSet, HighhHumidityRecordSet, HighWindrunRecordSet, LowHumidityRecordSet, HighPressureRecordSet, LowPressureRecordSet, LongestDryPeriodRecordSet, LongestWetPeriodRecordSet, HighTempRangeRecordSet, LowTempRangeRecordSet will all return 1 from when relevant record is set for the period of time set here (default 24 hours) and then reset to 0.
|}
 
5,838