5,838
edits
m (→Section: Station: see http://sandaysoft.com/forum/viewtopic.php?f=11&t=2237) |
|||
|-
|AvgBearingMinutes=N
|This parameter (attribute=value) is added directly to the file, it does not appear on a configuration screen. This line can be added in the [Station] section of the Cumulus.ini, with this parameter N is the number of minutes over which Cumulus calculates (by treating the wind as a vector and taking into account the speed as well as direction) its average bearing. Without it, the default sampling time = 10 minutes.
See next parameter for behavoir when calm.
|-
|UseZeroBearing=0
|Set this in the Station Configuration Screen Settings block.
*0 = Disabled, Cumulus displays the current bearing read from the station (i.e. the last direction the wind was blowing from before it became calm). Note that the average wind bearing will always display zero bearing if there has been no wind for the last N minutes (where N is defined by previous parameter if present but defaults to 10), as the average bearing takes wind speed into account.
*1 = Enabled, Cumulus display a bearing of zero (and '---' for the compass point) when the wind is calm (note when not calm, bearing is 360 for true North)
|-
|CalculatedDP=0
|
edits